5.1.0 5.0.0 4.8.4 4.7.1
5.1.0 5.0.0 4.8.4 4.7.1

HxMap 5.1 Release Notes

Main features

  • Ingest and process datasets captured with Leica CityMapper-3, DMC-5 and DMC-5X. The image field of view definition selected in flight planning is automatically applied during ingest.

  • Product resolution for the project can be applied at image ingest workflow step.

  • Apply a custom tile index in 3D Advanced product generation for true ortho products.

  • Update calibration of bathymetric lidar sensor in CoastalMapper for new aircraft installations.

  • Lidar matching smoothing filter is improved to provide more consistent results in areas with multiple strip overlaps.

  • Optionally apply a datum transformation during ground point import.

Main fixes

  • Select calibration page in ingest wizard did not display the location metadata and used oldest camera calibration’s as validity start date.

  • Update georeference with new trajectory did not work on cluster.

  • Triangulation datum parameterization settings were applied even when parametrization was deactivated.

  • Locked images could be adjusted by regional radiometry edits.

  • Load lidar captures to lidar viewer toolbar button was disabled when image captures were also selected.

  • Auto color correction in radiometry specification was not applied to oblique images in blockwide radiometry.

  • 3D Editor perspective 3D View point cloud display could not be filtered by class.

  • Workflow Manager would crash when Triangulation project was refreshed while Measurement window was open.

Upgrade Notes

  • In future releases HxMap will require CPUs with support for AVX2 instructions. Most newer (2013 and newer for Intel, 2015 and newer for AMD) CPUs support AVX2. Please check your specific computers where HxMap is run and plan to upgrade as needed.

  • Sensor system and FlightPro version compatibility has been updated, review the compatibility matrix HxMap 5.1 sensor system and FlightPro compatibility.

  • Global calibration repository now supports a post-fix on version folders to make them unique. The post-fix must start with underscore '_' and can be any string of numbers or letters after.

    • Example: for CityMapper-3 61211 delivered with exchangeable oblique lens kit

      • calibration version for 112 mm oblique lenses: CM3_61211\v001_S

      • calibration version for 146 mm oblique lenses: CM3_61211\v001_H

  • 3D Advanced includes a technology preview of true ortho generation from gaussian splats for hybrid datasets. See the information block in 3D Advanced Product Generation for details on how to create the product.

  • Data Copy now allows copying CoastalMapper sessions in two runs. Copy MM1 and MM2 first to create the session in the destination, then connect MM3 to MM6 to add the bathymetric sensor data.

  • Lidar QC report is improved to have a consistent graphic size independent of the flight line heading.

  • Column configuration in Triangulation perspective Points view is now saved for the local user.

  • Validation criteria for associating orthos to a mosaic scenario have been relaxed to allow ortho products with different radiometry specifications in the same mosaic.

  • Reduce forward overlap feature in image Ingest is deprecated. The option is still shown in the Ingest wizard product settings for images, but is not applied.

  • HRQLSIIHA sensor in SPL100HA was previously defined with Unknown sensor type. Calibration files in existing calibration repository and in existing datasets should be updated with sensor type HRQLSIIHA before processing in HxMap 5.1.

Known Issues

  • Ingest of RCD30 CH82 with 53 mm lens gives incorrect results. Continue using HxMap 5.0 for ingest.

  • Point cloud ground classification run on datasets ingested with waveform attributes will change the attribute values of individual points. Do not use ground classification on these datasets.

  • Project calibration from Triangulation for systems with RCD30 (SPL100, Chiroptera5, TerrainMapper, CityMapper) only includes the system calibration file. Copy the RCD30 geometry and radiometry calibration files along with lidar sensor calibration files from the session /cam folder to the project calibration before using for ingest.